UV Absorption Cells for Fluorimetry in High Temp. Fused Design

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2006

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
101~500 square meters
Management System Certification
ISO 9001
  • UV Absorption Cells for Fluorimetry in High Temp. Fused Design
  • UV Absorption Cells for Fluorimetry in High Temp. Fused Design
  • UV Absorption Cells for Fluorimetry in High Temp. Fused Design
  • UV Absorption Cells for Fluorimetry in High Temp. Fused Design
  • UV Absorption Cells for Fluorimetry in High Temp. Fused Design
  • UV Absorption Cells for Fluorimetry in High Temp. Fused Design
Find Similar Products

Basic Info.

Model NO.
QS-215
Disposable
Non-Disposable
Certification
CE, ISO, RoHS
Material
Glass
Bottle Top
Stopper Cover
Capacity
7ml
Construction Tech
High Temp. Fused
Windows
4
Surface
60/40
Polish
2 Lambda
Solvents
Organic
Quartz Grade
Synthetic Jgs1
Transport Package
2PCS/Box
Specification
pathlength 20mm
Trademark
ZhiCheng
Origin
China
HS Code
90279090
Production Capacity
500PCS/Month

Product Description

Discover the exceptional quality of our Synthetic UV absorption quartz cuvettes with stopper, meticulously designed for superior performance in Fluorimetry applications. These versatile cuvettes also offer impressive utility as alternatives for dye laser applications.
Item code: QS-215
External Dimensions: Height 48mm x Width 12.5mm x Depth 22.5mm, incorporating the elegant design of the stopper in the overall height.
Pathlength: 20mm. For your convenience, we also offer a range of pathlengths including 5mm, 10mm, 20mm, 30mm, 40mm, and 50mm. Simply send us an inquiry to customize your order to your needs.
Number of Windows: 4
Constructed with the utmost precision: fully high temperature fused. It is crafted through an advanced fire-fusing process, endowing them with exceptional robustness and the ability to withstand even the most corrosive chemicals.
UV Absorption Cells for Fluorimetry in High Temp. Fused DesignWe utilize premier synthetic quartz, known as JGS1 in China, setting the benchmark for quality. Unlike common quartz used by some to manipulate market prices, our top-grade quartz ensures superior performance. The following picture demonstrates the evident distinction:
UV Absorption Cells for Fluorimetry in High Temp. Fused Design
UV Absorption Cells for Fluorimetry in High Temp. Fused DesignSpectrophotometer data conveys undeniable proof of quality:
Item No. Model A
190.00 nm
B
200.00 nm
C
210.00 nm
D
220.00 nm
E
230.00 nm
F
240.00 nm
G
250.00 nm
H
260.00 nm
1  0-1 T% 80.1 82 83.3 83.9 84.4 84.8 85.1 85.3
2  1-1 T% 80.2 82 83.4 84 84.4 84.9 85.2 85.3
3  1-2 T% 81.3 82.5 83.6 84 84.5 85 85.2 85.4
4  1-3 T% 80.9 82.4 83.6 84 84.5 84.9 85.2 85.4
5  1-4 T% 80.4 81.8 83 83.8 84.2 84.7 84.9 85.1
6  1-5 T% 80.8 82.2 83.3 84 84.4 84.9 85.1 85.3
7  2-1 T% 80.6 82.2 83.3 84 84.6 85.1 85.1 85.3
8  2-2 T% 80.5 82.3 83.5 84.1 84.7 85.1 85.2 85.4
9  2-3 T% 80.4 82.1 83.3 84 84.5 85 85.1 85.3
10  2-4 T% 81.2 82.4 83.4 84.2 84.6 85.1 85.2 85.4
11  2-5 T% 79.5 81.2 82.5 83.4 84 84.6 84.7 85.1
12  3-1 T% 81.2 82.6 83.5 84.2 84.8 85.2 85.2 85.5
13  3-2 T% 81 82.4 83.4 84.2 84.7 85.2 85.2 85.5
14  3-3 T% 81.1 82.6 83.6 84.3 84.8 85.2 85.3 85.5
15  3-4 T% 81.3 82.7 83.7 84.5 84.9 85.3 85.4 85.6
16  3-5 T% 80.5 82.5 83.6 84.4 84.8 85.2 85.3 85.5
17  4-1 T% 78.1 81.1 82.6 83.5 84 84.5 84.7 85
18  4-2 T% 80.6 82.3 83.3 84.1 84.5 85 85.1 85.4
Frankly speaking, the quality of material is pivotal to cuvette performance. Our use of the top-grade quartz JGS1—renowned globally and comparable to Corning or Heraeus—guarantees unmatched reliability.

We extend our expertise to offer:
Firstly: Standard cuvettes designed for dual-way light transmission:
1. Standard cuvette with a secure lid,
2. Standard cuvette with a durable stopper,
3. Micro Cuvettes featuring black walls, with lid and stopper options,
4. Cylindrical cuvette with stopper,
5. Fully Customized solutions.
UV Absorption Cells for Fluorimetry in High Temp. Fused DesignSecondly: Fluorescence cuvettes offering four-way light passage for enhanced analysis:
1. Standard fluorescence cuvettes with stopper,
2. Micro cuvette available with lid or stopper,
3. Jumbo cuvettes tailored for fluorescence applications,
4. Bespoke Customized options.

UV Absorption Cells for Fluorimetry in High Temp. Fused Design
We warmly invite you to send us your inquiries regarding our cuvettes. We are committed to providing you with unparalleled service, not only in terms of pricing but across all aspects of your purchase experience.
Thank you for considering us as your trusted partner.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier