Dye Laser Fluorimeter Cuvette with High Sensitivity for UV Absorption

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2006

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
101~500 square meters
Management System Certification
ISO 9001
  • Dye Laser Fluorimeter Cuvette with High Sensitivity for UV Absorption
  • Dye Laser Fluorimeter Cuvette with High Sensitivity for UV Absorption
  • Dye Laser Fluorimeter Cuvette with High Sensitivity for UV Absorption
  • Dye Laser Fluorimeter Cuvette with High Sensitivity for UV Absorption
  • Dye Laser Fluorimeter Cuvette with High Sensitivity for UV Absorption
  • Dye Laser Fluorimeter Cuvette with High Sensitivity for UV Absorption
Find Similar Products

Basic Info.

Model NO.
QS-216
Disposable
Non-Disposable
Certification
CE, ISO, RoHS
Material
Glass
Bottle Top
Stopper Cover
Capacity
10.5ml
Construction Tech
High Temp. Fused
Windows
4
Surface
60/40
Polish
2 Lambda
Solvents
Organic
Quartz Grade
Synthetic Jgs1
Transport Package
2PCS/Box
Specification
pathlength 30mm
Trademark
ZhiCheng
Origin
China
HS Code
90279090
Production Capacity
500PCS/Month

Product Description

Introducing our meticulously engineered Synthetic UV Absorption Quartz Cuvettes featuring a precision stopper, perfect for Fluorimetry applications. These cuvettes are not only ideal for this use but also serve as premium substitutes in select dye laser operations.
Item Code: QS-216
External Dimensions: Height 48mm x Width 12.5mm x Depth 32.5mm, all measurements include the stopper.
Pathlength: 30mm. We provide an extensive range of sizes from 5mm to 50mm. Kindly reach out with your inquiry to receive your desired specifications.
Windows: 4
Expertly constructed with high temperature fused technology, these cuvettes promise unmatched durability.Crafted through an intricate fire-fusing process, our cuvettes boast extraordinary resilience and chemical resistance, standing strong even against harsh corrosive substances.
Dye Laser Fluorimeter Cuvette with High Sensitivity for UV AbsorptionOur cuvettes, crafted from premium synthetic quartz known as JGS1 in China, are distinguished from the ordinary options saturating the market. While some competitors opt for less costly quartz to lower prices, our superior quality is evident. Observe the remarkable difference in the subsequent image:
Dye Laser Fluorimeter Cuvette with High Sensitivity for UV Absorption
Dye Laser Fluorimeter Cuvette with High Sensitivity for UV AbsorptionSpectrophotometer data offers irrefutable evidence of our unmatched quality:
Item No. Model A
190.00 nm
B
200.00 nm
C
210.00 nm
D
220.00 nm
E
230.00 nm
F
240.00 nm
G
250.00 nm
H
260.00 nm
1  0-1 T% 80.1 82 83.3 83.9 84.4 84.8 85.1 85.3
2  1-1 T% 80.2 82 83.4 84 84.4 84.9 85.2 85.3
3  1-2 T% 81.3 82.5 83.6 84 84.5 85 85.2 85.4
4  1-3 T% 80.9 82.4 83.6 84 84.5 84.9 85.2 85.4
5  1-4 T% 80.4 81.8 83 83.8 84.2 84.7 84.9 85.1
6  1-5 T% 80.8 82.2 83.3 84 84.4 84.9 85.1 85.3
7  2-1 T% 80.6 82.2 83.3 84 84.6 85.1 85.1 85.3
8  2-2 T% 80.5 82.3 83.5 84.1 84.7 85.1 85.2 85.4
9  2-3 T% 80.4 82.1 83.3 84 84.5 85 85.1 85.3
10  2-4 T% 81.2 82.4 83.4 84.2 84.6 85.1 85.2 85.4
11  2-5 T% 79.5 81.2 82.5 83.4 84 84.6 84.7 85.1
12  3-1 T% 81.2 82.6 83.5 84.2 84.8 85.2 85.2 85.5
13  3-2 T% 81 82.4 83.4 84.2 84.7 85.2 85.2 85.5
14  3-3 T% 81.1 82.6 83.6 84.3 84.8 85.2 85.3 85.5
15  3-4 T% 81.3 82.7 83.7 84.5 84.9 85.3 85.4 85.6
16  3-5 T% 80.5 82.5 83.6 84.4 84.8 85.2 85.3 85.5
17  4-1 T% 78.1 81.1 82.6 83.5 84 84.5 84.7 85
18  4-2 T% 80.6 82.3 83.3 84.1 84.5 85 85.1 85.4
Fundamentally, the material defines functionality. Our cuvettes utilize top-tier JGS1 quartz, globally acknowledged as equivalent to Corning and Heraeus standards.

Furthermore, we proudly offer:
First: Standard Cuvettes for dual light passage:
1. Standard cuvette complete with a lid,
2. Standard cuvette equipped with a stopper,
3. Micro cuvettes with a black wall, including both lid and stopper,
4. Cylindrical type cuvette, complete with stopper,
5. Bespoke designs crafted to your unique specifications.
Dye Laser Fluorimeter Cuvette with High Sensitivity for UV AbsorptionSecond: Fluorescence Cuvettes for quadruple light passage:
1. Standard fluorescence cuvettes with stopper,
2. Micro cuvette offering the choice of a lid or stopper,
3. Jumbo cuvettes specifically designed for fluorescence,
4. Options for customization are readily available.

Dye Laser Fluorimeter Cuvette with High Sensitivity for UV Absorption
We warmly invite your inquiries about our cuvettes. Our dedication is to deliver not just competitive pricing, but also unparalleled service quality.
We thank you sincerely for considering us to meet your cuvette requirements.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier